Step Up to the Plus

Outperforms Commodity Panels

Huber Blue Plus™ OSB flooring is a superior alternative for the builder who uses commodity panels. You can upgrade to a product backed by a no sand guarantee, while offering your customers an extended warranty.

  • Fully sanded top surface
  • Enhanced moisture protection
  • Nail grid pattern for 16", 19.2" and 24" O.C.
  • Ships with protective side covers

Certification & Code Compliance

Panels are manufactured in conformance with PS2, Performance Standard for Wood-Based Structural-Use Panels. They are certified to be in conformance with requirements for U.S. Department of Housing and Urban Development (HUD/FHA).

Available in Select Markets Only

Huber Blue Plus is only available in select markets. Please contact Huber Engineered Woods at 1-800-933-9220 to speak with a sales representative.

 

Specifications

PANEL SIZES:
4'x8'
THICKNESS:
23/32"
EDGE:
Tongue & groove (Net face width is 47-1/2" on tongue & groove panels)
SHIPMENT INFORMATION:
- 45 pieces per unit
- 12 units per full truckload
 


Moisture Resistance
Enhanced moisture protection, backed by 100-day no sand guarantee.

Peace of Mind
Backed by a 50-year limited warranty and a company you can trust.

 


Huber Blue Plus Installation

Step 1: Position Panels

Install over two or more spans with certification stamp facing down. Ensure 1/8" gap between all panels.

Step 3: Cutouts

Make cutouts for plumbing and electrical, oversized by at least 1/4".

 

Step 2: Fasten Panels

Fasten using nails or screws, along with glue for greater floor stiffness.

Step 4: Apply Floor Coverings

Carpet and pad may be installed directly over panels.

 

Fire Rating

Huber Blue Plus™ panels are Class C (III) flame spread rated without need for test or label by HUD/FHA Manual of Acceptance Practices, Section 405-8 to the Minimum Property Standards.

 

UNIFORM LOAD TABLE (loads in psf)
For Subfloors and Single-Layer Floors
Span
Rating
(inches)
Thickness
(inches)
Load
Governed by
Strength Axis Perpendicular to Supports
(Inches, Center-to-Center of Supports)
Strength Axis Parallel to Supports
(Inches, Center-to-Center of Supports)
12 16 19.2 24 30 32 36 40 48 12 16 24
24" o.c. 23/32" L/480
L/360
L/240
L/180
Bending
Shear
975 368 201 98 48 39 34 25 16
1,305 491 269 130 64 52 46 33 21
1,958 736 403 195 96 78 69 49 32
2,610 982 537 260 128 104 91 66 43
642 361 251 160 103 90 57 46 32
476 345 282 222 175 164 139 125 108
263 99 33
350 132 44
525 198 67
700 263 89
321 180 64
476 345 213

*10 psf dead load assumed, live load deflection limit is L/360